Home Page > Our Products > Ultrafast High Voltage Gas-filled Switches


Ultrafast gas-filled switch HWG-1

Ultrafast high voltage gas-filled switches for handling high energy pulses. The unit consist of gas-filled peaking and ultrafast switching spark-gaps. Ultrafast high voltage gas-filled switches has the following performances and exterior:

 Operating voltage    150-500 kV 
 Current in pulse     up to 6 kA 
 Pressurization
 
 SF6
or mixture of SF6 and N2 
 Maximum pressure    14 atm 
 Dimensions:
  Maximum diameter
  Maximum length
 
    150 mm
    180 mm
  

HWG-1 spark gap is used for driving the electrodynamic structures of pulsed beamless microwave generators and commutation of high-power current pulses. HWG-1 spark gap can be used for switching high-power current pulses.

Two-channel ultrafast gas-filled switch CG-1

The two-channel ultra-fast-speed, high-voltage gas-filled CG-1 spark gap is used for driving the electrodynamic structures of beamless pulsed high-power generators. This ultra-fast-speed gas-filled spark gap has the key performances, as given in the Table.

Key Performances of CG-1 Spark Gap:

 Operating voltage    300-600 kV 
 Current in pulse     up to 10 kA 
 Pressurization
 
 SF6
or mixture of SF6 and N2 
 Maximum pressure    12 atm 
 Dimensions:
  Maximum diameter
  Maximum length
 
    70 mm
    180 mm
 Number of Channels    2 
  

The two-channel CG-1 spark gap, too, can be used for switching high-power current pulses.

Two-channel ultrafast gas-filled switch CG-2

The two-channel ultra-fast-speed, high-voltage gas-filled CG-2 spark gap is used for driving the electrodynamic structures of beamless pulsed high-power generators. This ultra-fast-speed gas-filled spark gap has the key performances, as given in the Table.

Key Performances of CG-2 Spark Gap:

 Operating voltage    400-700 kV 
 Current in pulse     up to 15 kA 
 Pressurization
 
 SF6
or mixture of SF6 and N2 
 Maximum pressure    14 atm 
 Dimensions:
  Maximum diameter
  Maximum length
 
     120 mm
     180 mm
 Number of Channels    2 
  

The two-channel CG-2 spark gap, too, can be used for switching high-power current pulses.


Information about IEMR   Departments   Products   Research Projects
Electromagnetic Phenomena Journal   Contact us